Available pages:
Impeller horizontal pumps KAN
material versions of pumps KAN and composition of some materials
Used materials in pumps KAN
Pump part Standard acid-resistant version Other materials
Cast parts in contact with pumped liquid GX5CrNiMo19-11-2 (1.4408) GX5NiCrMoCuTi25-21-4
carbon cast steel
Joint GX5CrNiMo19-11-2 (1.4408) cast iron
carbon cast steel
Bearing body cast iron  
Shaft
Shaft protective sleeve
X6CrNiMoTi17-12-2 (1.4571) C45, X1NiCrMoCu25-20-5, X30Cr13, X17CrNi16-2, X2CrNiMoN22-5-3

Notes

  • On customers wish, we can use other materials according to previous agreement
  • The chemical resistance of pump corresponds to the chemical resistance of materials used for pump parts being in contact with pumped liquid

Chemical composition (in %) of some materials

Grade mark C Mn Si
max
P
max
S
max
Cr Ni Other
components
Steel resistant to corrosion according to PN-EN 10088
X30Cr13
(1.4028)
0,26÷0,35 max 1,5 1,0 0,040 0,030 12÷14 - -
X6CrNiMoTi17-12-2
(1.4571)
max 0,08 max 2,0 1,0 0,045 0,030 16,5÷18,5 10,5÷13,5 Mo 2,0÷2,5

Ti 5xC÷0,7
X1NiCrMoCu25-20-5
(1.4539)
max 0,02 max 2,0 0,7 0,030 0,010 19÷21 24÷26 Mo 4,0÷5,0

Cu1,2÷2,0
Cast alloy steel resistant to corrosion
GX5CrNiMo19-11-2
(1.4408)
0,07 max 1,5 1,5 0,040 0,030 18÷20 9÷12 Mo 2,0÷2,5
GX5NiCrMoCuTi25-21-4 0,06 1,2÷2,0 0,17÷1,0 0,045 0,030 20÷22 24÷26 Ti 5xC÷0,7

Mo 4,0÷5,0

Cu 1,3÷1,8
TOFAMA S.A.
87-100 Toruń
ul. Marii Skłodowskiej-Curie 65

NIP 879-017-09-00, REGON 870305792
Sąd rejestrowy:Sąd Rejonowy w Toruniu

VII Wydział Gospodarczy Krajowego Rejestru Sądowego
Numer w rejestrze KRS: 0000058346
Kapitał zakładowy 1.930.826,67 zł
Kapitał wpłacony 1.930.826,67 zł
tel. 0-56/619 5201
fax 0-56/619 5431
e-mail: marketing@tofama.eu
Projekt i wykonanie
CenterNET S.A.